Fitting Extender
Quickly cap every open connector on a pipe fitting with a short pipe stub, so unfinished routing is easy to spot and measure.
General Description
Fitting Extender adds a 25 cm pipe stub to every unconnected connector of the pipe fittings you select. Each stub is created directly from its own connector, so its diameter and piping system always match — you don't need to configure anything before running it. Connectors that are already joined to another element are left untouched.
It's a quick way to visualize which sides of a fitting still need routing, or to leave a short, easy-to-find placeholder segment while you finish a layout.
Key Features
- Works on the current selection, or prompts you to pick pipe fittings if nothing is selected.
- Adds a stub only to connectors that are actually open — connected ones are skipped.
- Each stub matches its own connector's diameter and piping system automatically.
- Continues through the rest of the batch if one connector can't be extended, instead of stopping the whole operation.
Requirements
- At least one pipe fitting, either pre-selected or picked when prompted.
- A default pipe type must be defined in the project (Revit uses this to create the stub).
Usage Procedure
- Select one or more pipe fittings, or leave nothing selected.
- Open Fitting Extender from the MEP panel on the Frata ribbon tab.
- If nothing was pre-selected, pick the pipe fittings when prompted.
- The tool creates a 25 cm stub at every open connector on the selected fittings.
Recommendations
- Use it right after placing fittings to immediately see which connectors still need a real pipe run.
- If a connector can't be extended (for example, the fitting has no valid level), that connector is simply skipped — the rest of the batch still completes.